   Product Description

Cisco PWR675 (RPS675 / PWR675-AC-RPS-N1=) Full English Description

Product Overview

The Cisco PWR675, formally designated RPS 675 (Order Part:PWR675-AC-RPS-N1=), is an external rack-mountable 675W Redundant Power System (RPS) designed to provide transparent backup power for legacy Cisco Catalyst fixed switches. It serves as a secondary external power backup unit, not an internal hot-swappable chassis PSU. When a connected switch’s built-in power supply fails, the RPS675 delivers power with ultra-fast failover to avoid switch reboot and network downtime. This unit ships with one dedicated RPS connection cable.
Important Note: This hardware is End-of-Sale (EoS) legacy equipment. It requires proprietary Cisco RPS cables to connect to supported switches and cannot directly power network hardware without compatible cabling. It can back up up to six connected devices, yet onlyone failed device receives backup power at the same time.

Key Features

  1. 675 Watt Total Continuous Power Capacity
    Supports dual DC output voltages:+12V for non-PoE switches and -48V for PoE-enabled switchesrunning IP phones and wireless access points. Failover latency is less than 60 microseconds to prevent connected switches from restarting during primary PSU failure.
  2. Universal Wide-Range Global AC Input
    Worldwide auto-ranging mains specification:
  • Input Voltage: 100 VAC ~ 240 VAC
  • Operating Frequency: 50 Hz – 60 Hz
  • Standard IEC C14 inlet for AC mains power cord
  1. External 1RU Rack-Mount Form Factor
    Designed for standard 19-inch equipment racks, can also be deployed on desktops. Equipped with six independent RPS output ports.
    Important Note: Use only official Cisco CAB-RPS series proprietary cables. Not compatible with modern Catalyst 3650/3850/9000 switches, ISR 4000 routers, Firepower security appliances, or RPS2300 cabling.
  2. Non Hot-Swap Main Chassis
    The RPS675 unit itself must be fully powered down for maintenance. Connected switches remain online during automatic power failover events.
  3. Front Panel LED Status Monitoring
    Visible status LEDs indicate AC input status, DC output channel activity, fan operation, temperature and fault alarms. Supported switches can report RPS operational status via Cisco IOS for SNMP remote monitoring.
  4. Multi-Layer Hardware Protection
    Integrated overvoltage protection (OVP), overcurrent protection (OCP), overtemperature protection (OTP), surge protection and short-circuit protection to protect the RPS unit and connected LAN infrastructure.
  5. Dual-Tier Power Protection Deployment
    Can work alongside external UPS systems: UPS provides hold-up power during mains blackouts, while RPS675 protects against sudden internal switch power supply breakdowns.

Supported Hardware Platforms

  • Catalyst 2950 / 2970 / 2900 LRE XL Series
  • Catalyst 3550 / 3560 / 3560V2 / 3750 / 3750V2 Series
Not compatible: Catalyst 3650, 3850, 9000 series, ISR4000, ASR routers, Firepower appliances.

Typical Application Scenarios

  • Legacy campus and branch VoIP networks using Catalyst PoE access switches
  • Mission-critical enterprise LAN environments requiring minimal downtime
  • Retail, education and healthcare sites with IP telephony and wireless access points
  • Unmanned remote network sites with high availability requirements
  • Spare backup power upgrade for existing legacy Catalyst switch deployments

Technical Specifications

  • Form Factor: External 1RU rackmount Redundant Power System (RPS)
  • Input Type: Universal 100–240 VAC wide-range AC, 50/60 Hz
  • Rated Total Output Power: 675W
  • Supported Output: +12VDC / -48VDC
  • Hot Swappable (RPS Unit): No
  • Maximum Connected Switches: Up to six units (single active backup channel)
  • Mandatory Accessory: Cisco proprietary CAB-RPS connection cable
  • Compliance: UL60950-1, EN60950-1, FCC Class A, CE certified, RoHS compliant

Short Version for E-commerce Listing

Cisco PWR675 (RPS675, PWR675-AC-RPS-N1=), 675W External Legacy Redundant Power System for Catalyst 2950/3550/3560/3750 Series Switches. 1RU rackmount design with universal 100–240VAC input, <60µs seamless failover supporting both PoE and non-PoE switches. Features comprehensive hardware protection circuits and front status LEDs. Suitable for high-availability legacy enterprise LAN and VoIP branch deployments.
Click:26 Entry Time:2026-08-03 【Print】 【Close

 © 2026 Kino Technology Limited. All Rights Reserved. | Hong Kong Registered · Shenzhen Operation    | Original  Brand New  & Original Brand Used Network Communication  Equipment Supplier 

Links:   Kino Technology Ltd   |  
Kino Technology Limited   网站技术支持:未来互联