Homepage | Collection | 繁体中文
Product
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
H3C
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
Contact Us


Company Name:Kino Technology Limited

Website:www.kino86.com

Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China



Contact Person:kiki

Tel :+8613040881925 

E-mail:kiki@szkiki.com

Wechat:+8613040881925

Whatspp: +8613040881925

Teams:kiki@szkiki.com





Products
 Product >> Cisco >> ALL
 
Product_Id:
8312305316
ProductName:
C9404-FAN
Specification:
Product Notes:
Product Category:
Cisco
 
   Product Description

Cisco C9404-FAN Full English Description

Product Overview

The Cisco C9404-FAN is an integrated hot-swappable fan tray exclusively designed for the Cisco Catalyst 9404R modular 4-slot chassis switch. This complete fan tray contains eight independent fans arranged in two rows of four, delivering side-to-side airflow to cool supervisors, line cards, power supplies and internal chassis components. Only one fan tray bay exists on the C9404R chassis; a fully functional fan tray is mandatory for safe switch operation.
Important Note: This fan tray is chassis-specific. It cannot be interchanged with C9407-FAN (for C9407R) or C9410-FAN (for C9410R). The tray supports servicing from both front and rear of the rack. Operating the switch without an installed fan tray will trigger critical thermal alarms and can cause permanent hardware overheating damage.

Key Features

  1. Intelligent Variable Speed PWM Thermal Control
    Each internal fan independently adjusts rotational speed based on real-time chassis temperature, altitude and traffic load. It reduces RPM under light workloads to lower acoustic noise and accelerates airflow automatically during high thermal loads. It supports standard operating mode and NEBS-compliant fan profiles.
  2. Side-to-Side Airflow Architecture
    Airflow Direction: Side-to-side airflow (intake from one side of chassis, exhaust from opposite side), the standard thermal design for Catalyst 9400 series modular switches. Optimized for enterprise wiring closet and data center hot/cold aisle containment deployments. Maximum airflow reaches minimum 640 CFM at full throttle.
  3. OIR (Online Insertion and Removal) Support
    Engineers can replace the entire fan tray without powering down or rebooting the Catalyst 9404R switch. The tray features dual handles and captive screws for convenient tool-free installation and removal from either the front or rear rack side.
  4. Front Panel Visual Status LED & Remote Monitoring
    Built-in status LED on the front face of the fan tray:
  • Solid Green: All fans operating normally
  • Amber / Flashing Amber: Individual fan stall, hardware fault or abnormal thermal status
    IOS XE captures environmental events, generates logs and sends SNMP traps to centralized monitoring systems when fan faults occur. Equipped with UHF RFID tag for automated asset tracking.
  1. Multi-Fan Internal Redundancy
    Eight separate fans inside one tray. If a single fan fails, remaining working fans ramp up speed to sustain cooling capacity. Administrators should replace the fan tray promptly once any fan fault is detected to eliminate thermal risk.
  2. Enterprise-Grade Durability
    Industrial long-life fan assembly engineered for 24/7 continuous operation in core and distribution network environments. Designed to dissipate heat generated by high-density 10G/25G/40G line cards and high-power PoE modules.

Supported Hardware Platforms

  • Catalyst 9404R (4-slot modular chassis)
Not compatible: Catalyst 9407R, Catalyst 9410R, Catalyst 9200/9300 stackable switches, all Nexus 9000 data center switch platforms.

Typical Application Scenarios

  • Enterprise core & distribution layer deployments based on Catalyst 9404R modular switches
  • Spare replacement fan tray for failed cooling assemblies on Catalyst 9404R chassis
  • High-density 10G/25G campus networks with PoE/UPOE line cards generating heavy thermal load
  • Mission-critical LAN infrastructure requiring non-disruptive hot-swap hardware maintenance

Technical Specifications

  • Form Factor: Integrated full fan tray with 8 independent fans (2 rows × 4 fans)
  • Airflow Direction: Side-to-side chassis airflow
  • Maximum Airflow: Minimum 640 CFM at full speed
  • Hot Swappable: Yes (OIR supported, serviceable front and rear)
  • Monitoring: Front status LED + IOS XE environmental monitoring, SNMP traps, RFID asset tag
  • Operating Ambient Temperature: -5°C ~ +45°C
  • Power Source: Supplied by switch chassis backplane
  • Compliance: UL60950-1, EN60950-1, FCC Class A, CE certified, RoHS compliant

Short Version for E-commerce Listing

Cisco C9404-FAN hot-swappable fan tray for Catalyst 9404R 4-slot modular switch, equipped with 8 independent fans delivering side-to-side airflow. Supports OIR online replacement, variable-speed PWM thermal regulation and IOS XE environmental monitoring. Designed for enterprise core and distribution layer network deployments.
Click:35 Entry Time:2026-08-03 【Print】 【Close

 © 2026 Kino Technology Limited. All Rights Reserved. | Hong Kong Registered · Shenzhen Operation    | Original  Brand New  & Original Brand Used Network Communication  Equipment Supplier 

Links:   Kino Technology Ltd   |  
Kino Technology Limited   网站技术支持:未来互联