| Product Description |
Cisco N7K-C7009-FAN Full English Description
Product Overview
The Cisco N7K-C7009-FAN is a hot-swappable integrated system fan tray exclusively designed for theCisco Nexus 7009 (N7K-C7009) 9-slot modular data center switch chassis. It delivers side-to-side forced airflow to cool supervisor modules, I/O line cards, fabric modules and internal chassis hardware. The Nexus 7009 chassis accommodatesone single N7K-C7009-FAN, mounted on the rear side of the chassis. A fully functional fan tray is mandatory for safe continuous equipment operation.
Important Note: This fan tray is chassis-specific hardware and cannot be interchanged with fan assemblies for Nexus 7004, 7010, 7018 or any other Nexus platform. Individual fans inside the tray are not field-replaceable; the entire tray must be swapped if any internal fan fails. During fan tray removal, operators must complete replacement within several minutes. If cooling is lost for an extended period, the chassis triggers thermal protection shutdown to avoid permanent hardware damage caused by overheating.
Key Features
-
Intelligent Variable-Speed Thermal Regulation
The fan tray dynamically adjusts fan rotational speed based on real-time chassis temperature, operating altitude and thermal load of installed modules. Fans run at low RPM under light workloads to minimize acoustic noise, and automatically increase airflow when internal temperatures rise. All thermal status metrics are reported to Cisco NX-OS for continuous environmental monitoring.
-
Side-to-Side Airflow Architecture
Airflow Direction: Air intake from chassis right side → exhaust toward chassis left side. This native airflow design matches Nexus 7009 mechanical layout. Sufficient clearance must be reserved on both sides of the chassis to avoid blocking intake/exhaust vents, complying with standard hot-aisle / cold-aisle data center deployment standards.
-
OIR (Online Insertion and Removal) Support
Technicians can replace the complete fan tray without powering off or rebooting the Nexus 7009 switch. Maintenance operations are carried out from the chassis rear panel, supporting non-disruptive servicing for mission-critical core data center networks. Proper ESD protection procedures are required during replacement.
-
Status LED & Remote Environmental Monitoring
Built-in status LED on the fan tray rear panel provides instant local visual indication:
-
Solid Green: All internal fans operate normally
-
Solid Amber/Red: Fan fault detected
NX-OS generates environmental syslog entries and sends SNMP traps to centralized monitoring systems immediately upon detection of fan abnormalities.
-
Internal Fan Redundancy Design
Multiple independent fan units are integrated into a single tray assembly. If one fan malfunctions, remaining operational fans automatically ramp up speed to maintain temporary minimum cooling capacity. Administrators should arrange replacement promptly to eliminate thermal operation risks.
-
Data Center-Grade Reliability
Industrial long-life bearing fan assembly engineered for 24/7 continuous operation in enterprise and carrier-grade data center core environments. Optimized to dissipate heat generated by high-density 10G / 40G Ethernet line cards, redundant supervisors and fabric modules.
Supported Hardware Platforms
-
Cisco Nexus 7009 Modular Switch Chassis (N7K-C7009)
Not compatible: Nexus 7004, Nexus 7010, Nexus 7018, Nexus 9000 series, Catalyst 6500 / 4500 series switches and all Cisco router platforms.
Typical Application Scenarios
-
Data center core layer deployments built on Nexus 7009 modular switches
-
Spare replacement cooling assembly for failed fan trays on Nexus 7009 chassis
-
Network environments equipped with high thermal-density 10G/40G line cards
-
Mission-critical enterprise and carrier data center infrastructure requiring hot-swappable maintenance
Technical Specifications
-
Form Factor: Dedicated integrated rear-mounted fan tray for Nexus 7009 chassis
-
Airflow Direction: Side-to-side (right intake, left exhaust)
-
Hot Swappable: Yes (OIR supported under NX-OS)
-
Power Feed: Powered via chassis backplane
-
Monitoring: Rear status LED + NX-OS environmental logging & SNMP traps
-
Operating Ambient Temperature: 0°C ~ +40°C
-
Compliance: UL60950-1, EN60950-1, FCC Class A, CE certified, RoHS compliant
Short Version for E-commerce Listing
Cisco N7K-C7009-FAN hot-swappable fan tray dedicated for Cisco Nexus 7009 9-slot modular switch chassis with side-to-side airflow. Supports OIR online replacement without equipment outage and NX-OS variable-speed thermal management. Mandatory cooling component for Nexus 7009 data center core switches.
|
|
|