|
Company Name:Kino Technology Limited
Website:www.kino86.com
Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China
Contact Person:kiki
Tel :+8613040881925
E-mail:kiki@szkiki.com
Wechat:+8613040881925
Whatspp: +8613040881925
Teams:kiki@szkiki.com
|
|
|
| Product >> Cisco >> ALL |
| |
|
Product_Id: |
831532916 |
ProductName: |
NXA-FAN-65CFM-PE |
Specification: |
|
Product Notes: |
|
Product Category: |
Cisco |
| |
|
| Product Description |
Cisco NXA-FAN-65CFM-PE Full English Description
Product Overview
The Cisco NXA-FAN-65CFM-PE is a variable-speed, hot-swappable fan module for high-density Cisco Nexus fixed-form-factor data center switches. It deliversPort-side Exhaust (Back-to-Front) airflowwith maximum airflow capacity of 65 CFM and is identified by ablue handle marker. Its direct counterpart isNXA-FAN-65CFM-PI, which provides Port-side Intake (Front-to-Back) airflow with burgundy handle marking.
Important Note: All fan modules and power supplies installed within one chassismust adopt identical airflow direction. Mixing PE (exhaust) and PI (intake) airflow modules is unsupported and causes thermal imbalance, hotspots and overheating risks. Each fan module contains dual independent internal rotors. If one rotor fails, the remaining rotor offers temporary partial cooling; the entire fan FRU needs full replacement upon module fault. Standard ESD anti-static procedures must be followed during removal and installation.
Key Features
-
Intelligent Variable-Speed Thermal Regulation
The fan module dynamically adjusts rotational speed based on real-time internal chassis temperature, operating altitude and thermal load of active ports. Fans operate at low RPM under light workloads to reduce power consumption and acoustic noise, and automatically ramp up speed to boost airflow as temperatures rise. Continuous thermal telemetry data is transmitted to Cisco NX-OS or ACI firmware for comprehensive environmental monitoring.
-
Back-to-Front (Port-side Exhaust) Airflow Architecture
Airflow Direction: Cool air enters from chassis rear, and hot air exhausts out of the front port panel. This airflow scheme fits rack deployments where switch port panels face the hot aisle. Operators must keep intake and exhaust openings unobstructed to maintain rated cooling efficiency.
-
OIR (Online Insertion and Removal) Support
Technicians can replace the fan module without powering off or rebooting the host Nexus switch. All maintenance operations are carried out via rear fan bays, supporting non-disruptive servicing for leaf and aggregation fabrics. Sufficient functional fan modules must stay installed during replacement activities to avoid thermal protection shutdown.
-
Visual Status LED & Remote Monitoring
Built-in status LED provides instant local visual feedback:
-
Solid Green: All internal rotors operate normally
-
Solid Amber/Red: Rotor fault or over-temperature alarm detected
NX-OS generates environmental syslog entries and sends SNMP traps to centralized monitoring systems immediately once fan anomalies are detected.
-
Dual-Rotor Internal Redundancy
Two independent rotors are integrated inside each fan tray. If one rotor malfunctions, the second rotor delivers temporary limited cooling capacity. Administrators should arrange replacement promptly to eliminate thermal single-point-of-failure risks.
-
Data Center-Grade Reliability
Brushless DC industrial fan assembly engineered for 24/7 continuous operation in enterprise and cloud data center leaf layers, optimized for high-density 25G/100G fixed port switches under heavy traffic workloads.
Supported Hardware Platforms
Compatible Cisco fixed switches include:
N9K-C9336C-FX2, N9K-C93240YC-FX2, N9K-C9364C, N9K-C93360YC-FX2
Not compatible: Nexus 9500/9800 modular chassis, legacy Nexus 9300-PX/TX/PQ Gen1 switches, Nexus 3000 older generations, Catalyst switching platforms.
Typical Application Scenarios
-
Leaf fabric deployments on Nexus 9000 FX/FX2 fixed switches running standalone NX-OS or ACI fabric mode
-
Spare replacement cooling module for port-side exhaust configured Nexus high-density fixed switches
-
Data center rack layouts requiring port-facing hot-aisle deployment
-
Mission-critical cloud and enterprise infrastructure requiring hot-swappable non-disruptive maintenance
Technical Specifications
-
Form Factor: Single hot-swappable fan module
-
Part Number: NXA-FAN-65CFM-PE
-
Maximum Airflow Rate: 65 CFM
-
Airflow Direction: Back-to-Front (Port-side Exhaust, blue handle)
-
Reverse Airflow Counterpart: NXA-FAN-65CFM-PI (Front-to-Back / Port-side Intake, burgundy handle)
-
Hot Swappable: Yes (OIR supported under NX-OS / ACI firmware)
-
Internal Structure: Dual independent rotors
-
Monitoring: Status LED + NX-OS environmental logging & SNMP traps
-
Operating Ambient Temperature: 0°C ~ +40°C
-
Compliance: UL60950-1, EN60950-1, FCC Class A, CE certified, RoHS compliant
Short Version for E-commerce Listing
Cisco NXA-FAN-65CFM-PE variable-speed hot-swappable fan module with 65 CFM maximum airflow, Back-to-Front port-side exhaust airflow (blue marker). Supports OIR online replacement and NX-OS dynamic thermal speed adjustment. Cooling spare for Nexus 9336C-FX2, 93240YC-FX2 and other FX/FX2 series high-density fixed data center switches.
|
|
|
| Click:22 Entry Time:2026-08-03 【Print】 【Close】 |
|
|
|
|