Homepage | Collection | 繁体中文
Product
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
H3C
没有小类
没有小类
没有小类
没有小类
没有小类
没有小类
Contact Us


Company Name:Kino Technology Limited

Website:www.kino86.com

Address :Room 312, Honghua Building, No. 1 Guangyayuan Road, Bantian Street, Longgang District, Shenzhen city, Guangdong Province, China



Contact Person:kiki

Tel :+8613040881925 

E-mail:kiki@szkiki.com

Wechat:+8613040881925

Whatspp: +8613040881925

Teams:kiki@szkiki.com





Products
 Product >> Cisco >> ALL
 
Product_Id:
831519316
ProductName:
N2K-C2248-FAN
Specification:
Product Notes:
Product Category:
Cisco
 
   Product Description

Cisco N2K-C2248-FAN Full English Description

Product Overview

The Cisco N2K-C2248-FAN is a hot-swappable integrated fan tray developed for Cisco Nexus 2000 Series Gigabit Fabric Extenders (FEX). It deliversPort-side Exhaust (Back-to-Front) standard airflow. Its reversed airflow counterpart isN2K-C2248-FAN-B, which supports Port-side Intake (Front-to-Back) airflow.
Important Note: All fan trays and power supplies installed in the same FEX chassismust adopt identical airflow direction. Mixing PE and PI airflow components will trigger thermal imbalance, hotspots and overheating failures. The tray integrates multiple independent fans; partial cooling remains available if one fan fails, but the entire fan FRU needs complete replacement upon tray-level fault. Standard ESD anti-static procedures are mandatory during removal and installation.

Key Features

  1. Intelligent Variable-Speed Thermal Regulation
    The fan tray dynamically adjusts fan rotational speed based on real-time internal chassis temperature, operating altitude and traffic thermal load. Fans operate at low RPM under light workloads to reduce power consumption and acoustic noise, and automatically accelerate to boost airflow when internal temperatures rise. Continuous thermal telemetry data is transmitted to NX-OS running on the parent Nexus switch for comprehensive environmental monitoring.
  2. Back-to-Front (Port-side Exhaust) Airflow Architecture
    Airflow Direction: Cool air enters from the rear of the FEX chassis, and hot air exhausts out of the front port panel. This airflow design fits rack deployments where the FEX port panel faces the hot aisle. Operators must ensure intake and exhaust openings remain unobstructed to maintain rated cooling efficiency.
  3. OIR (Online Insertion and Removal) Support
    Technicians can replace the fan tray without powering off the Fabric Extender or disrupting upstream network traffic. Maintenance operations are completed via the front panel fan bay of the 1RU FEX chassis, supporting non-disruptive data center operations.
  4. Visual Status LED & Remote Monitoring
    Built-in status LED provides instant local visual feedback:
  • Solid Green: All internal fans operate normally
  • Solid Amber: Fan fault or over-temperature alarm detected
    NX-OS generates environmental syslog entries and sends SNMP traps to centralized monitoring systems immediately once fan anomalies are detected.
  1. Multi-Fan Internal Redundancy
    Multiple independent fans are integrated within a single tray assembly. If one fan unit malfunctions, remaining fans deliver temporary limited cooling capacity. Administrators should arrange replacement promptly to eliminate thermal risks.
  2. Data Center-Grade Reliability
    Industrial brushless DC fan assembly engineered for 24/7 continuous operation within enterprise and cloud data center access fabrics, optimized for Nexus 2000 series Gigabit FEX workloads.

Supported Hardware Platforms

Compatible Cisco Nexus Fabric Extenders:
N2K-C2224TP, N2K-C2248TP, N2K-C2248TP-E
Not compatible: Nexus 9000 fixed/modular switches, Nexus 5500/7000 standalone switches, Nexus 2232PP, Nexus 2300 series FEX and Catalyst switching platforms.

Typical Application Scenarios

  • Gigabit server access fabric deployments using Nexus 2224TP / 2248TP / 2248TP-E FEX connected to Nexus 5000/5500 parent switches
  • Spare replacement cooling fan tray for port-side exhaust configured Nexus 2200 GE FEX
  • Data center rack layouts requiring port-facing hot-aisle deployment
  • Enterprise and cloud infrastructure requiring hot-swappable non-disruptive hardware maintenance

Technical Specifications

  • Form Factor: Integrated hot-swappable fan tray for 1RU Nexus 2000 FEX
  • Part Number: N2K-C2248-FAN
  • Airflow Direction: Back-to-Front (Port-side Exhaust / Standard Airflow)
  • Reverse Airflow Counterpart: N2K-C2248-FAN-B (Front-to-Back / Port-side Intake)
  • Hot Swappable: Yes (OIR supported under NX-OS)
  • Monitoring: Front-panel status LED + NX-OS logging & SNMP traps
  • Operating Ambient Temperature: 0°C ~ +40°C
  • Compliance: UL60950-1, EN60950-1, FCC Class A, CE certified, RoHS compliant

Short Version for E-commerce Listing

Cisco N2K-C2248-FAN hot-swappable integrated fan tray with Back-to-Front port-side exhaust airflow. Supports OIR online replacement and NX-OS dynamic thermal speed control. Official cooling spare for Nexus N2K-C2224TP, N2K-C2248TP and N2K-C2248TP-E Gigabit Fabric Extenders.
Click:106 Entry Time:2026-08-03 【Print】 【Close

 © 2026 Kino Technology Limited. All Rights Reserved. | Hong Kong Registered · Shenzhen Operation    | Original  Brand New  & Original Brand Used Network Communication  Equipment Supplier 

Links:   Kino Technology Ltd   |  
Kino Technology Limited   网站技术支持:未来互联